Centrifugal Pump Optimization: 500 Designs, Two Better Pumps

A water pump designed in CFturbo was optimized in seven geometric parameters with TCAE and TOPT. Five hundred automated CFD runs were stored in a TBASE database, and surrogate models were trained on them. The study produced two improved pumps from the same data:

Duty-point design. Optimized for the duty flow rate (0.126 m³/s) only. Hydraulic efficiency rises from 91.1 % to 94.2 % at the same head, but at high flow rates it falls about ten points below the CFturbo baseline.

Wide-range design. Chosen with three flow rates in view. It reaches about 92 % at the duty point and stays 0.8 to 2.5 efficiency points above the baseline from 83 % to 150 % of the duty flow.

7
Design Variables
500
Designs in the Campaign
91.1 → 94.2 %
Duty-Point Design: Efficiency at the Duty Point, Same Head
+0.8 to +2.5
Wide-Range Design: Efficiency Points over the Baseline

The optimized pump is one result. The explored design space is the lasting engineering asset.

Why This Study Matters

Improving the hydraulic performance of a centrifugal pump is rarely a matter of changing a single dimension. Blade angles, blade count, impeller width and volute geometry interact, and a few manually selected variants cannot describe a seven-dimensional design space.

This study follows one pump through the whole chain. TCAE connects parametric geometry, automatic meshing and CFD in one repeatable workflow. TOPT runs it across the design space. TBASE keeps every result and turns the finished runs into models with known error, so that new questions are answered with a few extra CFD runs and not with a new campaign.

The study shows a workflow on a realistic pump. What the numbers can and cannot be used for is stated in the limits.

Study Overview

Question

How much can the hydraulic efficiency of a CFturbo pump design be improved at its duty point without changing the head, and what does that cost elsewhere on the pump curve?

Approach

One automatic TCAE workflow, a TOPT campaign of 500 designs in seven parameters (256 Latin hypercube samples, then 243 optimizer steps), a TBASE database of all runs, and surrogate models that proposed 65 further designs, each checked by CFD.

Finding

The campaign found most of the gain. At baseline head the efficiency rose from 91.08 % to 94.22 %. This duty-point design moves the best-efficiency point and loses up to 18 points at the highest flow rate.

Outcome

Two designs from one database. The duty-point design gives +3.1 points at the duty flow rate. The wide-range design gives +0.8 to +2.5 points from 0.105 to 0.189 m³/s and keeps the shape of the baseline curve.

Engineering Challenge

The starting point is a centrifugal pump designed in CFturbo. Its parametric CFturbo model is the baseline of this study and is rebuilt for every design. Improving its performance involves several strongly interacting geometric parameters. Blade angles, blade count, impeller width and volute geometry cannot be assessed independently, and evaluating all combinations directly with CFD is not practical.

The challenge is therefore not only to find a better design, but to establish an automatic and repeatable way of exploring the design space. Every candidate geometry must be generated, meshed, simulated and evaluated in the same way.

A second challenge appears after the optimum is found. A pump optimized for one flow rate is a different pump at every other flow rate. The result of an optimization is complete only with its pump curve.

Baseline designCFturbo pump design, parametric model

MachineSingle-stage centrifugal pump with volute, water

Speed1770 RPM

Duty flow rate0.126 m³/s

Baseline head at duty30.71 m

GoalHighest efficiency at the duty flow rate with head within ±1 % of the baseline

Baseline pump geometry from CFturbo: inlet pipe, impeller and volute.

Simulation Workflow

The optimization is an automatic loop. It starts with a set of design variables, creates a new geometry, meshes it, runs the CFD simulation and evaluates the result. The optimization algorithm then proposes the next parameter combinations. No run is set up by hand, and every input and result is stored.

CFturbo

Parametric impeller and volute, rebuilt for every design

TMESH

Automatic mesh, same settings for every design

TCFD

Steady CFD run: efficiency, head, power, cavitation, forces

TOPT

Sampling of the design space, then optimization

TBASE

One database, surrogate models with known error

CFD check

Model proposals simulated again in TCAE

The optimization loop: TOPT drives geometry generation, meshing and CFD.

Designs of the campaign passing through the same workflow.

CFD Simulation Setup

Geometry Builder: CFturbo

The pump geometry is created in the turbomachinery design software CFturbo. The whole loop is defined in the TOPT script, which runs the CFturbo geometry generation on a Windows computer, while meshing and CFD run on Linux.

The four components of the CFD model: inlet pipe, impeller, volute and outlet extension.

Mesh: Automatic Generation

Each candidate geometry is meshed automatically with snappyHexMesh in TMESH. The mesh is hex-dominant with local refinement around the blades and the volute walls and with three wall layers. The same meshing strategy is used for every design, so the results of different geometries are comparable.

Mesh of the baseline pump, about 2 million cells.

Physics and Boundary Conditions

The simulation is a steady, incompressible, turbulent flow of water. Turbulence is modelled with k-ω SST and wall functions. The impeller rotation uses the multiple reference frame (MRF) approach, which gives a steady representation of the interaction between impeller and volute. All averaged quantities are weighted by the flow rate.

Simulation typePump, steady state, incompressible

Components4

FluidWater

TurbulenceRANS, k-ω SST, wall functions

Rotation1770 RPM, MRF

InletTotal pressure 110 000 Pa

OutletVolumetric flow rate 0.126 m³/s

EfficiencyHydraulic, from the torque on the blade surfaces

StoppingConvergence check, at most 2500 iterations

One CFD runAbout 20 minutes on 32 cores

Optimization Setup

The study uses seven design variables. The number is a choice of the user, not a limit of the workflow. Together the parameters define the impeller and the volute while every design stays a realistic pump that can be generated, meshed and simulated automatically.

Parametric Space

ParameterMinimumCFturbo baselineMaximumDuty-point designWide-range design
Number of blades471176
Leading-edge angle, hub0.60.70990.80.540.6
Leading-edge angle, shroud0.220.32450.420.140.22
Trailing-edge angle, hub0.350.45560.550.42790.458
Trailing-edge angle, shroud0.270.37570.470.270.27
Impeller outlet width0.0320.0370.0420.038360.0409
Volute height0.10.15240.20.1380.1553

Angles are in radians as used by the CFturbo model. The two result columns are explained below. The duty-point design lies below the original minimum of two angles; see “Below the Original Limits”.

Latin Hypercube Sampling: Exploration

The first 256 designs are Latin hypercube samples. The range of every variable is sampled systematically, which covers the seven-dimensional space without an exhaustive combination of all values. At this stage designs with low efficiency are as valuable as good ones, because they describe how geometry and performance are related.

Efficient Global Optimization: Adaptive Search

The following 243 designs come from Efficient Global Optimization (EGO), an algorithm built natively into TCAE. It builds a Gaussian-process model of the objective from the runs already available and selects each new CFD run by expected improvement: either where the model predicts a better design, or where it is still uncertain. After each run the model is updated.

The Campaign in Motion

Evolution of the objective function during the campaign.

Campaign Results: 500 Simulations

494 of 500 runs gave a valid result; the other 6 failed in meshing.

Objective Function Evolution

Sampling (LHS)Optimizer (EGO)Model-guided CFD checksBest so farCFturbo baseline

Efficiency of every valid run in run order (16 runs below 80 % are not shown). The last group of points are the 30 model-guided designs computed in this study.

The sampling phase alone reached 93.69 %. The optimizer added a further 0.34 points, to 94.02 %. That best run, however, delivers 32.7 m of head instead of 30.7 m. It is a different pump.

Head Against Shaft Power for All Valid Designs

Each point is one CFD result at the duty flow rate. 78 designs form the front where no other design gives more head for less power. 10 campaign designs reach the baseline head or more with less power; the best of them, run 306, saves 1.9 %.

Valid designMost head for its powerBaseline head or more, less powerCFturbo baselineDuty-point design

At a fixed flow rate the hydraulic efficiency is proportional to head divided by power, so every straight line through the origin is a line of constant efficiency. Designs above the dashed line are more efficient than the baseline. The duty-point design is the result of the later model-guided steps and is not a campaign run.

Efficiency Against Head

Sampling (LHS)Optimizer (EGO)Model-guided checks

Each point is one CFD result (455 of 494 valid runs fall inside the plotted window). The shaded band is head within ±1 % of the baseline (30.71 m). The highest efficiencies of the campaign lie to the right of it, at higher head.

Knowledge Extraction

The optimized geometry is only one outcome. All runs were stored in one TBASE database, with the seven parameters and the result quantities of every design side by side, and a surrogate model was trained for each quantity.

The campaign database in TBASE.

A surrogate is only useful if its error is known. A fifth of the runs (99) was held back and predicted blind:

Accuracy on Held-Back Runs

QuantityR²Median errorInside 95 % interval
Efficiency0.9790.18 %90 %
Head0.9970.24 %92 %
Power1.0000.09 %84 %
NPSH required0.9851.00 %93 %
Axial force0.9970.45 %87 %
Radial force0.86510.01 %90 %

R² compares prediction with CFD. The last column is the share of CFD values inside the model’s own 95 % interval.

Which Parameters Matter

Relative importance of each parameter in the efficiency model (shares sum to 1).

Volute height, blade count and impeller outlet width explain most of the efficiency variation. A model answers in milliseconds, so the search for the best efficiency at baseline head ran over 250 000 candidate designs.

Model Proposals and CFD Check

DesignEfficiency predicted (95 % interval)Efficiency CFDHead predictedHead CFD
A: baseline head93.99 (93.61–94.37) %93.91 %30.87 (30.72–31.02) m30.90 m
B: head free94.38 (93.95–94.82) %93.66 %35.94 (35.72–36.15) m35.63 m

Proposal A, in the well-sampled part of the space, was confirmed inside its interval. Proposal B, at the high-head edge where few runs exist, was not: CFD gave 93.66 % against a predicted 94.38 %.

A model is a guide to the next CFD run, not a replacement for it.

Refinement

Five rounds of six CFD runs. Each round took the designs the models rated best at baseline head, computed them and added the results to the training data.

Head within ±1 % of baselineHead outside the bandBest so far in the band

Six CFD runs per round. After each round the models are trained again on all data. One design below 93.2 % in round 2 is not shown.

The efficiency in the head band settled at 94.07 % after two rounds. All 30 refined designs have seven blades, and all of them sit on the lower limit of three blade angles: the ranges, not the flow physics, stopped the search.

Below the Original Limits

Fourteen more CFD runs stepped below those three limits, one angle at a time and together.

Hub angle 0.54Hub angle 0.60

Efficiency below the original lower limit of the shroud leading-edge angle. The gain flattens between 0.18 and 0.12 and reverses at 0.10.

  • Leading-edge angle at the shroud is the only clear lever: from 94.07 % at the old limit to 94.22 % at 0.14, flat between 0.18 and 0.12.
  • Leading-edge angle at the hub has no measurable effect between 0.60 and 0.48.
  • Trailing-edge angle at the shroud adds 0.04 points but costs 0.4 m of head per 0.03 rad.
  • Total gain from extending the ranges: about 0.15 points. The original ranges were nearly sufficient.

The Duty-Point Design

CFturbo baseline impeller (red) and duty-point design (blue), seen from the inlet with the shroud removed. Both have seven blades. The leading edges sit at the same place; the new blades start at a flatter angle, and the outlet width parameter is 38.4 mm against 37.0 mm.
Velocity magnitude at the duty point in a section normal to the axis, CFturbo baseline (left) and duty-point design (right), same colour scale. Inside the impeller the velocity is relative to the rotating blades, in the volute it is the absolute velocity. Steady frozen-rotor result for one rotor position.

Side Effects at the Duty Point

QuantityCFturbo baselineDuty-point designChange
Efficiency (%)91.0794.22+3.14 points
Head (m)30.7231.00+0.9 %
Shaft power (kW)41.6240.59-2.5 %
NPSH required, 1 % criterion (m)7.235.55-23 %
Axial force magnitude (N)15741944+24 %

Cavitation margin improves together with efficiency. The axial force on the impeller grows by about a quarter and has to be checked against the bearing design. Both values come from the same CFD runs; nobody had to ask for them in advance.

What the Gain Costs: Pump Curves

The campaign optimized one flow rate. The complete curves of the baseline and the duty-point design show the whole picture.

CFturbo baselineDuty-point design
CFturbo baselineDuty-point design

Efficiency and head against flow rate at 1770 RPM. The dashed line marks the duty flow rate 0.126 m³/s. Hollow points did not settle within 2500 iterations and oscillate by 1 to 3 efficiency points: baseline at 0.063, 0.084 m³/s, duty-point design at 0.063, 0.084, 0.105, 0.1575, 0.168, 0.189 m³/s.

  • The CFturbo baseline has its best efficiency above the duty point: 93.1 % at 0.147 m³/s.
  • The optimization moved the best-efficiency point to the duty flow rate. At the duty point the gain is 3.1 points. Peak against peak it is about 1.1 points.
  • At higher flow rates the duty-point design is clearly worse than the baseline. A pump that often runs in overload needs a multi-point objective.

Second Objective: Keeping the Overload Range

A second TOPT campaign of the same pump and the same seven parameters computed every design at three flow rates: 0.056, 0.126 and 0.186 m³/s. It has 200 runs, of which 189 gave results at all three flow rates. Blade counts were limited to 5 to 9.

Before combining the two campaigns, the duty-point models from the first one predicted the duty-point results of the second one blind: the efficiency error was 0.39 points (root mean square) with no offset. The campaigns agree, so the duty-point models were trained on both.

With models for duty and overload efficiency, the search no longer has one answer. For each weighting of the two goals it returns a different design, always with the duty-point head within ±1 % of the baseline. Six designs along this trade-off were computed by CFD in each of three rounds.

The Trade-Off Between Duty and Overload

Three-flow-rate campaign, head at duty within ±1 %Model-guided designs, CFDChosen wide-range designCFturbo baseline

Every point is one design computed by CFD at both flow rates. Up and to the right is better. The 18 model-guided designs trace the edge of what the seven parameters allow at baseline head; 16 campaign designs fall inside the plotted window.

The models predicted the duty-point efficiency of these 18 designs with a median error of 0.05 points (largest 0.21) and the overload efficiency with a median error of 0.23 points (largest 2.01).

First Round of Six Designs

DesignBladesDuty 0.126 (%)Overload 0.186 (%)Part load 0.056 (%)Head at duty
CFturbo baseline791.0884.4664.76+0.0 %
Design 1793.9774.5767.63+0.7 %
Design 2693.5281.8266.53-0.2 %
Design 3693.0284.2064.82-1.0 %
Design 4 (wide-range design)692.6386.4865.39-0.3 %
Design 5692.0288.1464.45+0.1 %
Design 6691.0289.6662.90-0.6 %

Each step towards overload efficiency costs duty-point efficiency. The designs in the middle are better than the baseline at both flow rates. Design 4 was chosen as the wide-range design: six blades instead of seven, a larger volute and a wider impeller outlet than the duty-point design. All part-load values reached the iteration limit and are indicative only.

Three Pump Curves

CFturbo baselineDuty-point designWide-range design
CFturbo baselineDuty-point designWide-range design
Flow rate (m³/s)Baseline (%)Duty-point (%)Wide-range (%)DifferenceHead base (m)Head wide-range (m)
0.06370.8*73.8*67.8*-2.933.933.4
0.08478.4*81.8*78.5*+0.033.332.8
0.10584.690.7*85.4*+0.832.132.0
0.115588.293.689.3*+1.031.631.3
0.126 (duty)91.094.291.9+0.930.730.4
0.136592.993.493.7+0.829.529.2
0.14793.191.093.9+0.827.727.6
0.157592.288.4*93.2+1.025.525.6
0.16890.482.7*91.5+1.023.123.4
0.18982.864.8*85.4+2.517.618.4

* did not settle within 2500 iterations; such points oscillate by 1 to 3 efficiency points. Difference is wide-range minus baseline.

  • The wide-range design is better than the baseline at 8 of 10 flow rates, by 0.8 to 2.5 points. It is equal at 0.084 m³/s and lower at 0.063 m³/s, where neither run settled.
  • It keeps the shape of the baseline curve and lifts it. The duty-point design reshapes the curve: more at and below the duty point, much less above.
  • Which of the two is the better pump depends on how the pump is operated. The study delivers both, from the same database.

The duty-point value of the wide-range design depends on how the solver arrives there. Computed first, from the initial state, it settled at 92.63 %. In a curve computed from low to high flow rate it settled at 91.88 %, and in a curve computed from high to low flow rate at 92.59 %. At every other settled flow rate the two curves agree within 0.15 points, and the baseline shows no such effect (91.0 to 91.1 % on three paths). The curves and the table above use the low-to-high curve.

Engineering Insights

Insight 1

Parameterization defines what the optimization can discover.

All 30 refined designs piled up on the lower limit of three blade angles. Designs on a limit are a message about the ranges. Here extending them was worth 0.15 points.

Insight 2

Exploration found most of the gain.

The sampling phase alone reached 93.7 %. The optimizer and the model-guided runs added the rest, and the same samples later answered questions nobody had asked at the start.

Insight 3

A model is reliable where the space is sampled.

Proposal A, inside the sampled region, was confirmed by CFD within its interval. Proposal B, at the edge, was not. Every proposal on this page was checked by CFD.

Insight 4

The optimum depends on the question.

The best design for one flow rate loses up to 18 points in overload. With a second objective, 18 CFD designs mapped the trade-off and gave a pump that is better than the baseline from 0.105 to 0.189 m³/s.

Insight 5

Two campaigns became one database.

A blind check of one campaign against the models of the other showed that they agree. Their runs were then combined, and the second question needed no new campaign.

Insight 6

The explored design space is the lasting asset.

With the runs in TBASE, “same head”, “what about cavitation?” and “what about overload?” needed 65 extra CFD designs in total, not three new optimizations.

Possible Improvements

Experimental dataThere is no measurement for this pump and no mesh-independence study in this work. 

Transient modelSteady-state CFD with a rotating frame of reference is used; no transient rotor–stator interaction. Off-design points are indicative, and several did not settle within the iteration limit.

More complex efficiencyEfficiency comes from the blade torque. Disc friction, leakage and mechanical losses are not included.

Path dependenceOne design settled at two efficiency levels 0.75 points apart at the same flow rate, depending on the flow rate computed before it.

Wide-range design checked lessThe multi-point search stayed inside the original parameter ranges and blade counts 5 to 9. Cavitation and axial force were not evaluated for the wide-range design.

Structural or manufacturing checkNeither blade shape was checked for strength or manufacturability.

Software Used

Simulation software. This study used its TMESH module for meshing and its TCFD module for the flow simulation.

TCAE module for design of experiments and optimization. It ran both campaigns and all model-guided designs through the same project.

Simulation database with surrogate models. It holds the campaign results and trained the models used here.

The baseline pump and every design variant were generated with CFturbo, a product of CFturbo GmbH.

Downloads & Resources

centrifugal-pump-optimization-TCAE-Tutorial.zip

File size: 8.5 MB

Tutorial Features: PUMP, OPTIMIZATION, CFD, TCAE, TMESH, TCFD, SIMULATION, INCOMPRESSIBLE FLOW, STEADY-STATE, AUTOMATION, WORKFLOW, SNAPPYHEXMESH, 4 COMPONENTS, 3D, Finite Volume, CFD, OpenFOAM, k-ω-SST

Download This Tutorial


Yes, I have read the Privacy & Cookie Policy and agree to receive occasional email updates from CFD SUPPORT.

Related Knowledge & References

Questions about this study or a similar one for your pump? Contact CFD Support.